Quantum Instruments Splitter Boxes Manual de usuario Pagina 67

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 72
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 66
67
References
0
Power supplies 0
Power supplies for d.c. control circuits
Phaseo
®
regulated switch mode power supplies
ABL 7CEM single-phase regulated switch mode power supplies
Mains
input voltage
47...63 Hz
Output
voltage
Nominal
power
Nominal
current
Auto-protect
reset
Conforming
to standard
EN 61000-3-2
Reference Weight
V c V W A kg
a 100 to 240
single-phase
wide range
c 110 to 220 (1)
24 7 0.3 auto ABL 7CEM24003 0.150
15 0.6 auto ABL 7CEM24006 0.180
30 1.2 auto ABL 7CEM24012 0.220
ABL 7RE single-phase regulated switch mode power supplies
Mains
input voltage
47...63 Hz
Output
voltage
Nominal
power
Nominal
current
Auto-protect
reset
Conforming
to standard
EN 61000-3-2
Reference Weight
V c V W A kg
a 100 to 240
single-phase
wide range
24 48 2 auto ABL 7RE2402 0.520
72 3 auto no ABL 7RE2403 0.520
120 5 auto no ABL 7RE2405 1.000
240 10 auto no ABL 7RE2410 2.200
ABL 7RP single-phase regulated switch mode power supplies
Mains
input voltage
47...63 Hz
Output
voltage
Nominal
power
Nominal
current
Auto-protect
reset
Conforming
to standard
EN 61000-3-2
Reference Weight
V c V W A kg
a 100...240
single-phase
wide range
c 110...220 (1)
12 60 5 auto/man yes ABL 7RP1205 1.000
24 72 3 auto/man yes ABL 7RP2403 0.520
120 5 auto/man yes ABL 7RP2405 1.000
240 10 auto/man yes ABL 7RP2410 2.200
48 144 2.5 auto/man yes ABL 7RP4803 1.000
a 100 to 240
single-phase
wide range
24 480 20 auto/man yes ABL 7RPM24200 2.300
ABL 7REQ 2-phase regulated switch mode power supplies
Mains
input voltage
47...63 Hz
Output
voltage
Nominal
power
Nominal
current
Auto-protect
reset
Conforming
to standard
EN 61000-3-2
Reference Weight
V c V W A kg
a 380 to 415 24 120 5 auto/man no ABL 7REQ24050 0.850
240 10 auto/man no ABL 7REQ24100 1.200
ABL 7U 3-phase regulated switch mode power supplies
Mains
input voltage
47...63 Hz
Output
voltage
Nominal
power
Nominal
current
Auto-protect
reset
Conforming
to standard
EN 61000-3-2
Reference Weight
V c V W A kg
a 3x380 to 415 24 240 10 auto/man no ABL 7UEQ24100 1.200
480 20 auto/man no ABL 7UEQ24200 2.100
a 3x400 to 520 24 120 5 auto/man yes ABL 7UES24050 1.300
240 10 auto/man yes ABL 7UPS24100 1.300
480 20 auto/man yes ABL 7UPS24200 2.300
960 40 auto/man yes ABL 7UPS24400 4.500
(1) Compatible input voltage.
ABL 7CEM
108700-13-M
ABL 7RE2405
ABL 7RP2405
ABL 7RP4803
43367-15-M
ABL 7P
pppp
108387
ABL-7REQ
530894
ABL 7UPS
108387-25-M
Presentation :
pages
page 58, page 59
Characteristics :
pages page 62 - page 65
Dimensions :
page page 68
Schemes :
page
page 69
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
Vista de pagina 66
1 2 ... 62 63 64 65 66 67 68 69 70 71 72

Comentarios a estos manuales

Sin comentarios

Guardian Technologies Kohlenmonoxid (CO) -Detektoren Benutzerhandbücher

Die Liste der Guardian Technologies Kohlenmonoxid (CO) -Detektoren -Produkte enthält 1 Benutzerhandbücher für 1 diese Modelle. Alle PDF-Benutzerhandbücher können heruntergeladen oder online angezeigt werden.

Klicken Sie auf den Alphabet unten, um zur vollständigen Liste der Modelle zu gelangen, die mit diesem Buchstaben beginnen

Modelle Dokumententyp
PN 8402
Bedienungsanleitung   Guardian Technologies PN 8402 User's Manual, 10 Seiten